Connecting and configuring a scanner in IZI
Nội dung này hiện chưa có sẵn bằng ngôn ngữ của bạn.
Connecting and configuring a scanner in IZI
Section titled “Connecting and configuring a scanner in IZI”Scanning is available to all clubs without activation by Support. You need permission for the operation, products with barcodes in the catalog and a suitable scanner. Marked goods also require a configured cashbox and marking validation.
Choose settings for your scanner
Section titled “Choose settings for your scanner”The barcode type and the way data reaches the PC are separate settings. A 2D scanner usually reads both linear barcodes and Data Matrix: one device can serve both purposes.
| Type or input mode | Settings |
|---|---|
| Linear 1D scanner | USB HID Keyboard; enable the EAN-8/EAN-13 and Code128 formats you use; Enter suffix, or Tab; no arbitrary prefix, truncation or character replacement |
| 2D scanner for marked goods | USB HID Keyboard; enable Data Matrix and GS1 DataMatrix; preserve letter case, punctuation and GS; Enter or Tab suffix |
| Alt/keypad emulation or text injection | Original ASCII text including GS; verify the complete code in CRM. A working mode need not change just because the PC uses RU |
| COM/Serial, USB CDC | CRM does not read COM directly. Use a supported keyboard mode or existing keyboard wedge software |
Connect the device and configure the terminator
Section titled “Connect the device and configure the terminator”- Connect the scanner to USB. HID mode identifies it as a keyboard and normally needs no separate driver.
- Select USB HID Keyboard using your model’s manual.
- Enable Enter after each code, also called Add CR or Suffix: CR. CRM also accepts Tab.
- Disable arbitrary prefixes, truncation, character replacement and forced case conversion.
CRM has no scanner connection selector or COM port settings. Configure the device using its manual or vendor software. Do not scan programming barcodes intended for another model.
Additional Data Matrix settings
Section titled “Additional Data Matrix settings”Use a 2D scanner supporting GS1 DataMatrix. Disable case conversion, truncation and character replacement. Marking codes identify individual packages: preserve uppercase and lowercase letters, punctuation and invisible separators.
GS/FNC1 transmission
Section titled “GS/FNC1 transmission”FNC1 separates variable-length fields in GS1 DataMatrix. In transmitted text the separator is GS, ASCII 29, hex 1D. This differs from Enter, Tab and literal text such as <GS> or \u001d. GS1 guideline.
The marking dialog accepts the GS character itself, Ctrl+], or an unmodified F8 key. Select the appropriate control-character mode using the scanner manual. Do not replace GS with spaces, Enter or printed text.
CRM recognizes a leading ]d2 AIM identifier on GS1 DataMatrix; arbitrary prefixes are unnecessary. It can recover some missing separators or keyboard characters only when the cashbox confirms one unique candidate. This does not replace transmitting the complete original code.
Keyboard layout and Caps Lock
Section titled “Keyboard layout and Caps Lock”For ordinary USB HID keystrokes the recommended starting scanner profile is US / United States keyboard. This is a device setting. The operator does not need to change the PC layout before every scan.
| Scanner option | Meaning and check |
|---|---|
| Keyboard Country | Determines the keys sent for each character; start with US for ordinary HID |
| Caps Lock Override / Ignore Caps Lock | Helps preserve case with Caps Lock enabled; names and behavior vary by model |
| Convert Case | Preserve original case; disable forced uppercase or lowercase |
| Keypad / Alt emulation | Another transmission mode; keep a working mode that already preserves the complete code and GS |
Do not enable all options as a universal recipe. Follow manufacturer instructions, such as the separate parameters in the Zebra documentation.
Verify an ordinary barcode and a marking code
Section titled “Verify an ordinary barcode and a marking code”- Scan an ordinary barcode in a text editor; check the complete value and terminator.
- Open New order in CRM and scan a product barcode registered in the catalog. Check the selected product.
- For marked goods, wait for the marking dialog and scan the Data Matrix on that individual package.
- Check the cashbox result. If Caps Lock behavior makes the original case ambiguous, CRM submits the actual input text to the cashbox. If recognition fails, scan again; contact support if the error persists.
- Repeat with RU and EN, then Caps Lock off and on. The browser cannot always distinguish Caps Lock compensation modes, so recovery of the original case is not guaranteed for both modes. If results differ, check the device profile against its manual.
- As part of cashbox acceptance, perform an agreed sale and check the receipt.
A text editor only verifies text arrival. It may not display GS and does not establish cryptographic validation, marking-service availability or permission to sell.
The 6–64 characters without spaces restriction applies to ordinary product barcodes in the IZI catalog. Do not truncate marking codes to this length.
Ordinary and 2D scanners on one PC
Section titled “Ordinary and 2D scanners on one PC”Use one 2D scanner for both code types, or connect two devices. CRM has no scanner-type switch:
- Scan a product barcode in product search or a warehouse page.
- While the marking dialog is open, it owns the scan. The code must not add another product or open another order.
- After closing the dialog, scan the next product barcode.
Scan sequentially. Browsers receive HID scanner input as a keyboard stream and cannot reliably separate two devices scanning simultaneously.
Troubleshooting
Section titled “Troubleshooting”| Symptom | Check |
|---|---|
| No input even in a text editor | USB, power, HID mode and enabled symbologies |
| Product not found | Complete barcode in the product card, selected club and unwanted prefixes |
| Code appears but validation does not start | Enter/Tab suffix; the marking dialog also has a validation button |
| Missing characters or changed case | Keyboard Country, Convert Case, Caps Lock Override and truncation |
| Marking recovery is ambiguous | Scan again, verify GS and punctuation, or paste the complete original code |
| Scanning triggers a browser command | Control-character mapping; transmit GS using a supported mode inside the marking dialog |
| Cashbox unavailable | KkmServer on the cashbox PC and an active device |
| Cashbox prohibits sale | Exact marking response, package state and permit-regime settings; repairing input does not override a prohibition |
A scanner that irreversibly truncates data or changes case before transmission loses information. Correct its device profile. For Support, include the model, connection mode, keyboard profile, Caps Lock state, exact error and validation time.
Related
Section titled “Related”Câu hỏi thường gặp
Does Support need to enable scanning?
No. Scanning is available to all clubs. Staff need permission for the sale or warehouse operation.
Must the PC keyboard be switched to English?
No switch between RU and EN is required before every scan. Configure the scanner's keyboard country and data conversion using its model-specific manual.
Can a standard scanner read Data Matrix?
Marking requires a 2D scanner supporting Data Matrix and GS1 DataMatrix. A linear 1D scanner cannot read these symbols.
Can I connect a COM scanner?
CRM does not read COM directly. Select USB HID Keyboard if supported, or use existing software that delivers the scanner's data as keyboard input.
IZI LLC (ООО «ИЗИ»), TIN 7842227686, OGRN 1257800012249, office 1, premises 3-N, lit. A, 15-17 Perekupnoy lane, Saint Petersburg, 191024, Russia, admin@izi.is · Cookie settings